Programme Séminaire et Workshop: 19. infoExpo 2001

Lieu de séminaire et d’exposition: Centre Culturel " Vieux Moulins", St Prex

 

Programme Séminaire

Salle 1

Colonnes capillaires GC chirales, les applications
Prof. Rafael Tabacchi, Université Neuchâtel

Vu leurs propriétés en matière d'odeurs, de goûts et d'activités biologiques, les substances chirales sont présentes dans les domaines aussi variés que la parfumerie, l'alimentation, la pharmacie etc... Leur analyse s'impose, et pour ce faire, les colonnes chirales s'affirment comme un moyen incontournable.

SolGel Technology for more stable Capillary-GC Phases and higher Temperature Limits
Bernd Pfeffer, SGE (Deutschland) GmbH

This is a novel technic to modify the inner surface of fused silica capillaries, which gives very inert capillary columns. Another effect is the improved anchoring of the phases onto the fused silica surface. This results in higher temperature limits and less bleed with polar and non polar phases. This will be demonstrated with several examples on SolGel-1ms and SolGel-Wax.

Chromatographie en phase gazeuse multidimensionel: applications environnementales et chiralité
Luiz F. de Alencastro et Dominique Greandjean, EPFL Gestion des écosystèmes - Ecotoxicologie

Des applications pratiques de la MD-GC-ECD pour la séparation de mélanges complexes de substances halogenées seront presentées. L‘utilisation de deux fours independants contenant des colonnes de polarité differente permet une bonne identification de composés.

Méthode rapide d‘analyse par GC-MS des additifs naturels ou nature-identiques dans les aliments
Cong Khanh Huynh, Institut Universitaire Romand de Santé au Travail

La présente méthode permet de déterminer les additifs aromatiques dans les aliments pour animaux dans le domaine de 0.2 à 30 ppm. La méthode consiste en un enrichissement par micro-extraction à l‘aide d‘une fibre en quartz imprégnée d‘un polymère greffé chimiquement (Carbon™-PDMS) dans l‘espace de tête des échantillons solides (headspace-SPME). La fibre est ensuite désorbée directement dans l‘injecteur du GC à 280°C en mode „on-column“ et la quantification est faite après séparation sur colonne capillaire et détection par un détecteur MS Ion-Trap. La méthode est validée en comparant les résultats obtenus avec une méthode conventionnelle par extraction au bain ultrasonique utilisant de l‘acétone comme solvant d‘extraction. Elle présente les avantages de simplicité (pas de préparation), pas d‘utilisation de solvants organiques, de sensibilité et de rapidité (40 min par analyse au total). Elle est suffisament robuste pour une application entièrement automatique en routine avec une productivité accrue. La précision et la limite de détection de cette méthode sont suffisantes pour les analyses quantitatives.

Totalchrom en Fast GC avec Headspace, ATD ou GC/MS
Dr. Denis Rousseil, PerkinElmer instruments

TotalChrom, le grand frère de Turbochrom, rend possible les meilleurs rapports en chromatographie, grâce à son nouveau module TCPublisher. Nous verrons comment exploiter ces possibilités dans le cadre d'applications en FastGC sur AutosystemXL combiné avec des échantilonneurs Headspace ou désorbeurs thermiques. Par la même occasion, nous verrons comment faciliter et améliorer le travail du personnel de laboratoire: il suffit de connecter sur un seul et même système TotalChrom des instruments de fournisseurs variés et de générations différentes.
Avec ces nouveaux outils, nous cherchons à améliorer la productivité de votre laboratoire, que ce soit par la FastGC, des échantilonneurs qui évitent les extractions liquides, ou encore grâce à TotalChrom.

Thermal Desorption Applications
Dr. P. A. Weibel, MS Wil GmbH

The technique called “Short Path Thermal Desorption” permits direct thermal desorption of volatiles and semi-volatiles into the GC injection port. The Thermal Desorption Unit sits directly on top of the injection port of most commercial GC’s and the samples are desorbed directly into the GC injection port and column. Due to this “short Path” of sample flow, this system overcomes some of the problems known to previous systems by eliminating transfer lines (transfer lines are easily contaminated and cause memory effects) and by providing optimum delivery (maximum sensitivity) of samples to the GC.

The new designed PC controlled Automated Short Path Thermal Desorption System (AutoDesorb System) is designed for the continuous and unattended thermal extraction of volatile and semi-volatile organics from solid, liquid and gas samples for analysis by GC and GC/MS.

The field of applications, where the TD4 or the AutoDesorb System can be used is huge.

Thermo Finnigan – New Applications and Innovative Products for GC and GC/MS
Thomas Läubli, Brechbühler AG

An overview of the newest GC and GC/MS Techniques from ThermoFinnigan.
Newer GC Techniques include FAST GC and Large Volume GC plus a new Pulsed Discharge Detector for high selectivity and sensitivity in GC.

The different GC/MS Techniques with Quadrupole, IonTrap and TOF Instruments
are explained and the main application fields for each technique are shown.

 

Salle 2

The HPLC Column 250 x 4.6 mm - The Dinosaur dies slowly
Dr. Jürgen Maier-Rosenkranz, Grom GmbH

Several new strategies and requirements, like more sensivity, small amounts of sample, time saving, high number of samples, higher loading etc., forces more and more users to change from the common 125 x 4 / 4.6 or 250 x 4 / 4.6 mm columns to other sizes. Usually the columns become shorter: 20 up to 100 mm for saving time and for more sensivity.
In addition the ID decreases especially for the LC-MS down to 1 mm or smaller. Or the ID increases for higher loading to 8, 10 or 20 mm for preparative high speed separations.
Interactions and strategies for method development will be presented.

Optimizing your system for short HPLC columns
Ruedi Schwarz, sertec electronics

HPLC on the move. Today the Analyst takes more and more care about analysing time and consumption and disposing of effluents. To reach the targets he searches for new methods mostly in conjunction of shorter and smaller columns. The verification is often done on the existing HPLC equipment with unsatisfying results in the view of the chromatographer. The frustration is mostly due to very small traps within your system. Most of them can be removed with a little effort on the plumbing system as long you not entering the micro HPLC. We highlight the critical points and show how we can get around it.

Micro-HPLC - Basics and Applications
Dr. Harald Dibowski, Kronlab GmbH

Downscaling of high pressure liquid chromatography enables new dimensions of sensitivity and consumption costs. This seminar gives a short introduction with all necessary definitions for micro-LC. In comparison to conventional analytical HPLC with column inner diameters of 4 or 4.6 mm, the seminar shows the important differences with the usage of smaller columns e.g. capillary columns ID 320 µm or midbore columns ID 1mm.
All necessary technical realisations of micro-LC components pumps (splitless or split), mixing chambers, detector cells etc. are also described as different examples for increasing sensitivity (up to x2000) and cost reducing potential of samples and handling materials.
Additionaly new aspects of possible combination techniques LC-MS, LC-CE, CEC or field assisted micro-LC will be presented.

HPLC Fittings: selection criteria
Andreas Floderer, infochroma ag

If the fittings don't fit the valve, colunm or detector of an analytical instrument, the instrument can't be used effectively. The working pressure of an HPLC instrument is between 100 - 200 bar. At this pressure tubing and fitting have to be tightly fitted at each point of the system.
But which ones are the best suited fittings? Those that fit your system impeccably and don't leave a dead volume. Knowing the major differences of the fittings from different manufacturers (Swagelok, Parker, Valco, Waters, Rheodyne,Uptight) allow the analyst to choose among the alternatives. Important attributes are exchangeability, tolerances, concentric ID/OD and purity protocols.
Avoiding leaks and cloggings is essential in running an HPLC system effectively. Some selection criteria is given to avoid them .

MassLib pour l‘élucidation de structures
F. Friedli, MSP Friedli & Co.

La spectrometrie de masse, aussi bien qu’elle est établie comme méthode pour la détermination du poids moléculaire, est rarement appliquée pour l’élucidation de la structure chimique. La raison est bien simple : trop fastidieux et difficile paraît le processus de l’interpretation du spectre au non-spécialiste et plutôt non-utilisable pour ce processus se présentent les logiciels basés sur des recherches de spectres en bibliothèques.
MassLib en est une exception. Conçu pour le structural depuis son origine 30 ans dans le passé, il se présente aujourd’hui d’une façon conviviale et efficace avec ses recherches en similarité qui offrent de reconnaître des aspects structurals même si les spectres nous paraissent fortement dissimilaires. Recherche de fragments, neutres et structures en combinaison permettent d’attaquer le problème de structure inconnue aussi là où aucune quantité suffisante d’échantillon permetterait d’autre méthodes que la spectrometrie de masse

Autosampler Vials: which one to choose
Christian Baumli, infochroma ag

The possible combinations of vials, inserts and closures have increased dramatically over the last 25 years. What has to be considered is how to choose the right one.
The autosampler vial/closure system has to maintain the integrity of the sample by isolating the sample from its environment. The system should not interact with the sample itself. At the same time it has to be compatible with available instruments.
It will be discussed how various production processes for autosampler vials, production tolerances and measurments have changed with time.
Closure systems have to be resistent against solutions yet easy to pearce. Various closure systems will be compared and advantages and disadvantages discussed.
Work with small sample volumes will be also discussed and possible solutions compared.

 

Workshop GC

Installation du générateur GEMFID sur une GC Dani-Optimalisation
Huu-Phuoc Nguyen, BON Technologies SA

En pratique: MassLib pour l‘élucidation de structures
F. Friedli, MSP Friedli & Co.

Applications of the MS-NoVent System
Bernd Pfeffer, SGE (Deutschland) GmbH

Workshop HPLC

Discussion of different types of closures for autosampler vials using examples
Christian Baumli, infochroma ag

Optimizing your system for short HPLC colums in practice
Ruedi Schwarz, sertec electronics

HPLC: High Throughput, Method Development... - A round table discussion
Dr. Jürgen Maier-Rosenkranz, Grom GmbH

Micro-HPLC - let your own sample run on a Micro-HPLC System
Dr. Harald Dibowski, Kronlab GmbH

 

 